Home Services Support About infoMonitors About FSEC infoMonitors.com
 
Data Plots
Help
Data available from Jan. 15, 2003 to
Mar. 30, 2004
 
Quick Date:


Start Date:


End Date:


Summary Report
Building and PV Power
HVAC Power
Hot Water Power
Indoor Conditions
Ambient Conditions

Built by Loudon County Habitat for Humanity with assistance from Oak Ridge National Laboratory's Building Technology Center
1056 ft2 Unvented Crawlspace 6.5" R-20 SIP walls
Roof 8" R-28 SIP Windows U = 0.34
SHGC = 0.33
1.5-Ton SEER 13.7 Heat Pump
2.06 kWp PV System 48 - 43W Amorphous Silicon Modules Heap Pump Water Heater
ORNL Zero-energy House #1
Summary Report
Mar 29 2004, 00:15 -To- Mar 30 2004, 00:00 EST

Energy Use (KWh)
Total Building Power 14.6
Heat Pump 1.3
Inverter to House 8.7
Back to Utiltiy 5.3

Indoor Conditions

Avg

Min/Max
Indoor Temp (F) 78.3 76.4/ 80.2
Indoor RH (%) 45.3 41.2/ 53.9
Crawlspace Temp 63.6 61.5/ 66.3
Crawlspace RH 63.5 60.4/ 65.8

Ambient Conditions

Avg

Min/Max
Outside Temp (F) 68.3 58.6/ 79.2
Outside RH (%) 59.2 37.2/ 82.7
e-mail us