Home Services Support About infoMonitors About FSEC infoMonitors.com
 
Data Plots
Help
 
Quick Date:


Start Date:


End Date:


Summary Report
Indoor T & RH
Outdoor T & RH
HVAC Performance
Electric Usage
Natural Gas Usage
DHW Performance
AC Scatterplot


Select
"cp3 database

As part of the U.S. DOE Building America program, FSEC and CPS Energy are evaluating the performance of three homes in San Antonio, Texas with identical ~2,000 ft2 floor plans and orientation. One home built to builder standard practice serves as the control (CP1), while the other homes (CP2 & CP3) demonstrate high performance features.

Photvoltaic Home (CP3) Features:
- 37 HERS Index
- 2.4 kW roof-integrated PV array
- Sealed attic with R-28 spray polyurethane foam at the roof deck
- Frame walls with R-15 spray foam + R-3 rigid foam sheathing
- Energy Star windows, Uo = 0.34, SHGC = 0.32
- Enhanced air sealing
- SEER 18 air conditioner and 94% gas furnace
- Energy star appliances
- Fluorescent lighting package

Apr 05 2011, 00:15 -To- Apr 06 2011, 00:00 EST

Electricity Usage

kWh

KBtu's
Condenser unit 0.8 2.6
Air Handler 0.4 1.4
Total House (Grid+PV) 24.4 83.4
PV Production 13.1 44.7
Energy to Grid 6.0 20.4

Interior Conditions

Average

Min/Max
Thermostat Temp (deg.F) 75.7 73.5/ 77.6
Thermostat Humidity (%RH) 43.8 40.0/ 46.2
Sealed Attic Temp (deg.F) 75.5 71.4/ 79.6
Sealed Attic Humidity (%RH) 46.4 44.6/ 48.8

Ambient Conditions

Avg/Tot

Min/Max
Avg Temperature (deg.F) 59.0 37.3/ 77.1
Avg Relative Humidity (%RH) 34.4 13.9/ 70.2
Tot Horizontal Solar Radiation (W/m2) 28883.7 300.9

Natural Gas Usage

CuFt

KBtu's
Total House 41.8 42.6
Furnace 0.0 0.0
Range Top 0.0 0.0
Dryer 0.0 0.0
e-mail us